Home
Back
performance evaluation of XOANONS®WE-D8773
1.Foam-inhibition & defoaming in varnish(addition to total formulation)
Item Foam-inhibition Defoaming Compatibility
0.3%addition 0.5%addition
Similarproduct 3 3 3 2
XOANONS®WE-D8773 2 3 5 4
0=unavailable5=veryeffective
2.Static surface tension in varnish (25℃ mN/m)
Item Addition0.1% Addition0.3% Addition0.5% Addition0.8%
Similarproduct 26.475 25.925 25.642 25.658
XOANONS®WE-D8773 26.167 25.792 25.308 25.283
Static surface tension is a measurement of wetting and spreading ability on the solid surface at a balanced surface tension. Lower value of static surface tension,
higher performance of wetting and spreading. 3.Dynamicsurfacetension(25℃mN/m)
Item 100ms 111ms 125ms 143ms 167ms 200ms 250ms 333ms 500ms 1000ms
Similarproduct 74.5 71.8 68.8 63.8 55.8 47.0 41.6 39.0 37.3 35.3
XOANONS®WE-D8773 66.3 65.9 64.3 58.3 47.9 44.3 40.7 38.0 36.0 36.0
Dynamic surface tension(DST) measured by bubble tensiometer is a symbolic application data of additive activity in paint, which means the ability of additive
dissemination from liquid to paint surface. Lower value of DST, higher speed of leveling.
5.Wave-scandualandgloss
Comment dudullness Wa0,1-0,3mm Wb0,3-1,0mm Wc1-3mm Wd3-10mm We10-30mm DOI 20° gloss
Similarproduct 39.8 15.4 16.5 30.6 29.7 28.2 75.2 76.3
XOANONS®WE-D8773 39.9 13.1 15.2 31.9 29.2 26.8 75.3 76.2
long wave:1~30mm wave, can be watched in 3m distance. Lower value, better long wave leveling. short wave:0.1~1mm wave, can be watched in less than 3m distance. Lower value, better short wave leveling. du value:Less than 0.1mm wave can not be watched by eyes. DOI value:distinctness of image, showing the clearance of reflect gram. Higher value, better distinctness of image. The test dates provided by wave-scan dual reflect the effects of dry film leveling.

Shared by the following means: